How to Read an ENKORA SKU
One standard names and codes every product. Learn it once and you can read any ENKORA part number from a drawing or a label.

An ENKORA SKU isn't an internal code you have to look up. It's the product's specification, written in a fixed order. One exact orderable build gets one SKU, so every color temperature, protection class and length has its own code. Learn the order once and you can check a label against a drawing right there on site.
The Order of the Blocks
[SERIES]-[LED TYPE + DENSITY]-[POWER]-[VOLTAGE]-[CCT or COLOR]-[IP]-[WIDTH]-[LENGTH]
Take ES-COB146-P030-24V-4K-IP20-08-32FT:
| Block | Meaning |
|---|---|
ES | ESSENTIAL series |
COB146 | COB strip, 146 chips per foot |
P030 | 3.0 W per foot (the number is tenths of a watt) |
24V | 24 V DC |
4K | 4000K |
IP20 | IP20, for dry indoor locations |
08 | 8 mm wide |
32FT | 32.8 ft (10 m) reel |
Series Codes
| Code | Series |
|---|---|
| ES | ESSENTIAL |
| NW | NARROW |
| HE | HIGH EFFICACY |
| LR | LONG RUN |
| CR95 | HIGH CRI 95+ |
| HO | HIGH OUTPUT |
| SPI | ADDRESSABLE / SPI |
| NF | NEON FLEX |
| WW | WALL WASHER |
| HT | HIGH TEMPERATURE |
| FS | FLEXIBLE LED SHEET |
| UW | UNDERWATER |
The Details Worth Knowing
- Density is LEDs per foot for SMD and chips per foot for COB, rounded to a whole number.
- Power
Pxxxis always tenths of a watt per foot:P024is 2.4 W/ft,P146is 14.6 W/ft. Sheet products state watts per piece instead, such as15WPC. - Color temperature is abbreviated:
27K= 2700K,3K= 3000K,65K= 6500K. Single colors use a letter (R,G,B,Y), and color-mixing products useTW,RGB,RGBWorRGBTW. - Width below 10 mm is zero-padded:
05= 5 mm. A decimal width keeps its digit:028= 2.8 mm, never 28 mm. - Shaped products use a cross-section instead of a width:
16X16for a 16×16 mm neon,D18for an 18 mm round. - Geometry and features sit right after the series where they apply:
FCfor free cut,TB/SB/360for neon geometry,CMfor chain-modular wall washers. - Beam angle appears only where the optic is selectable:
BA30= 30°. - Length is the product or reel length, not the maximum run. They're two separate specifications.
Every product page decodes the selected SKU block by block, and each series page shows its own SKU format with a real example.
Frequently asked questions
What does P030 mean in an ENKORA SKU?
Power in tenths of a watt per foot: P030 is 3.0 W/ft, P024 is 2.4 W/ft and P146 is 14.6 W/ft.
Does the length in the SKU mean the maximum run?
No. The length block is the product or reel length. Maximum single-feed run is a separate specification listed on the product page.
Why does each color temperature have its own SKU?
ENKORA gives every exact orderable build its own SKU, so each color temperature, protection class and length can be ordered, stocked and matched precisely.
Specify with ENKORA
Working on a project? Send us the drawings and we will propose strips, profiles and drivers that fit together.